Epoch V2 Elite · Victron ready · IP67 dust-tight
A 48V 100Ah LiFePO4 battery engineered for serious off-grid, RV, marine, solar, and system-builder power applications.
The Epoch V2 Elite 48V 100Ah lithium battery is a 5.12kWh lithium battery built for high-performance 48V systems that need Victron CANbus communication, an IP67 dust-tight and immersion-rated enclosure, internal self-heating, Bluetooth monitoring through the included battery gauge, and 150A continuous discharge for up to 20 minutes. It is a premium 48V off-grid battery for builders who want higher efficiency, smaller wire gauges, cleaner installation, and rugged real-world reliability beyond indoor-only server rack batteries.
5.12kWh lithium storage for high-efficiency 48V architecture.
This 48V 100Ah LiFePO4 battery is built for the most demanding off-grid, RV, and marine systems, from large RV solar arrays and van power systems to electric marine propulsion support and remote cabins. A native 48V system can reduce current draw compared with lower-voltage architectures, helping builders use more efficient cable runs, cleaner busbar layouts, and larger inverter platforms.
With 5.12kWh of energy, 150A continuous discharge (up to 20 minutes at 150A), 300A peak output for 30 seconds, and Victron compatible communication, the Epoch V2 Elite gives professional installers and experienced DIYers a premium high-capacity 48V power bank that is built for harsh environments instead of climate-controlled server rooms.
Off-grid, RV, marine, solar, industrial, and 48V power systems.
Premium communication, sealed IP67 construction, heating, and battery intelligence.
Built-in CAN communication at 500 kbit/s supports compatible Victron Cerbo GX, Ekrano GX and other GX devices. The battery reports its status and charge limits, and with DVCC on it sets the charge voltage and current limits of Victron chargers.
Unlike indoor-only 48V server rack batteries, this battery has an IP67 enclosure: dust-tight and protected against temporary immersion in up to 1 m of water for 30 minutes. It is not rated for water jets, pressure washing or continuous submersion, so in RV bays, marine compartments, outdoor enclosures, and off-grid locations install it upright and secured against vibration, where it stays dry in normal use, with all harness connectors fully seated.
LiFePO4 cells must not be charged below 0°C (32°F). When a charge source is connected and the cells are too cold, the BMS holds off normal charging while the internal heater, powered by the charge source, warms the cells; charging resumes once they reach 5°C (41°F). With self-heating, charging is supported from -22°F / -30°C ambient, and discharge is available down to -4°F / -20°C without heating.
Bluetooth 4.0 through the included battery gauge connects to the Epoch Li-Ion app (iOS and Android) for state of charge, voltage, current, cell voltages, temperatures, history and warnings, and installs firmware updates over the air. With several batteries, the parallel view shows the whole bank.
Technical performance that separates this battery from generic 48V rack batteries.
Start with 5.12kWh. Scale to 81.9kWh.
As power needs grow, the Epoch V2 Elite can grow with the system. Wire up to 16 batteries in parallel to create a 48V bank with up to 1,600Ah of capacity and approximately 81.9kWh of stored energy. This makes it a strong platform for large off-grid homes, premium RV conversions, marine systems, and high-capacity backup power builds.
Clean technical table for system designers, installers, and off-grid builders.
| General | |
|---|---|
| Brand | Epoch Batteries |
| Model / SKU | C48100A |
| Series | V2 Elite Series |
| Battery type | Heated Bluetooth LiFePO4 deep-cycle battery with Victron communication |
| Primary applications | 48V off-grid, RV, marine, solar, backup, and high-power inverter systems |
| Chemistry | LiFePO4 / lithium iron phosphate |
| Cell configuration | 16S1P (100Ah cells) |
| Bluetooth | Yes — Bluetooth 4.0 through the included battery gauge; Epoch Li-Ion app (iOS and Android) |
| Victron communication | Yes — CAN bus at 500 kbit/s to compatible Victron GX devices (BMS-CAN or VE.Can port) |
| Internal heating | Yes |
| External controls | Power button on the battery; mountable ON/OFF switch and mountable battery gauge included |
| Cycle life | 3,500+ cycles to 70% remaining capacity (25°C, 0.5C charge, 1C discharge) |
| Voltage and capacity | |
| Nominal voltage | 51.2V (3.2V per cell) |
| Nominal capacity | 100Ah (0.5C, 25°C) |
| Energy capacity | 5.12kWh / 5,120Wh |
| Maximum voltage | 58.4V (3.65V per cell) |
| Minimum voltage | 40.0V (2.5V per cell) |
| Operating voltage range | 40.0V – 58.4V |
| Self-discharge | ≤3% per month (100% SOC, 25°C) |
| State of charge at shipment | 30% ± 3%; charge fully before first use |
| Current ratings | |
| Max continuous discharge | 150A (up to 20 minutes at 150A; not for cycling) |
| Peak discharge | 300A for 30 seconds |
| Max continuous charge current | 100A |
| Max short-duration charge current | 300A for 5 seconds |
| Theoretical continuous DC output | 51.2V × 150A = 7,680W DC, before inverter losses (up to 20 minutes) |
| Series and parallel configuration | |
| Series connections | No series connections; native 48V battery |
| Parallel connections | Max 16 batteries in parallel; set the DIP switches for the bank |
| Maximum parallel bank | Up to 1,600Ah / 81.92kWh at 51.2V nominal |
| Temperature | |
| Charge temperature range | -30°C to 55°C / -22°F to 131°F ambient, with self-heating |
| Cell charge temperature range | 0°C to 55°C / 32°F to 131°F |
| Discharge temperature range | -20°C to 55°C / -4°F to 131°F |
| Storage temperature, up to 1 year | 0°C to 35°C / 32°F to 95°F |
| Storage temperature, up to 1 month | -20°C to 45°C / -4°F to 113°F |
| Best performance | 15°C to 25°C / 59°F to 77°F |
| Self-heating | Yes — charging stops at 0°C and resumes at 5°C (cell temperature) while the heater, powered by the charge source, warms the cells |
| Mechanical | |
| Dimensions | 20.86 in L × 8.65 in W × 12.06 in H (529.8 × 219.8 × 306.3 mm; height including terminal posts) |
| Case height (body) | 11.54 in / 293.0 mm |
| Terminal spacing | 17.99 in / 457.0 mm, center to center |
| Weight | 97 lb / approx. 44 kg |
| Case material | ABS and PC blend (UL94 V-0) |
| Enclosure protection | IP67: dust-tight; temporary immersion to 1 m for 30 minutes. Not rated for water jets, pressure washing or continuous submersion |
| Terminals | M8 threaded; 8–12 N·m (71–106 lbf·in) |
| Mounting | Upright; six M8 nuts for the optional Epoch V2 & V2-T Mounting Hardware (8D battery bracket, sold separately), 125 mm (4.92 in) spacing |
| Recommended charging settings | |
| Charger type | Lithium (LiFePO4) compatible, CC/CV; program every charge source, including Victron equipment, to these settings |
| Absorption voltage | 56.8V |
| Absorption time | At least 15 minutes per battery in the bank |
| Float voltage | 54.0V |
| Re-bulk voltage | 53.2V |
| Equalization | Off / disabled |
| Temperature compensation | Disabled (0 mV/°C) |
| BMS high-voltage cutoff | 58.4V |
| SOC recalibration | 58.4V (manual); custom algorithm under Victron communication |
| Charge current | 100A maximum continuous per battery; 300A for up to 5 seconds |
| Victron setup | Use BMS-CAN (or VE.Can at 500 kbit/s), confirm the Epoch battery on the GX device, turn DVCC on, and set Epoch as the controlling BMS and the battery monitor |
| BMS protection and compliance | |
| Smart BMS protection | Overcharge, over-discharge, over-current, short circuit, high/low temperature disconnects |
| Overcharge protection | 3.65 ± 0.01V per cell (58.4V); release 3.45 ± 0.01V per cell (55.2V) |
| Over-discharge protection | 2.70 ± 0.05V per cell (43.2V); release 3.00 ± 0.05V per cell (48.0V) |
| Over-current protection | Charge 110A (release 90A) and discharge 350A, each after 5 seconds; short circuit 1,200A |
| Temperature protection | Charge: low 0°C (release 5°C), high 55°C (release 50°C). Discharge: low -20°C (release -17°C), high 55°C (release 50°C) |
| Self-consumption | 20mA powered on; 200µA powered off |
| Internal fuse | 270A rated (UL 60691, TEX150-R1N-XBZ); 1,200A transient overload for 3 seconds |
| Cell certifications | UL 1642, UL 9540A, IEC 62619:2022 |
| Additional compliance | CE, RoHS; UN 3480, Class 9 (transport) |
| Warranty | 11-year limited warranty: free repair or replacement in Years 1–5, then 40% off MSRP on a replacement battery in Years 6–11. Register within 90 days or keep your proof of purchase. |
Dust-tight, immersion-rated, and installed where it stays dry.
The IP67 enclosure is dust-tight and protected against temporary immersion in up to 1 m of water for 30 minutes (IEC 60529), making it far more flexible than indoor-only server rack designs. It is not rated for water jets, pressure washing or continuous submersion: secure the battery upright, keep it where it stays dry in normal use, protect wiring and ports, keep all harness connectors fully seated, and follow best practices for marine, RV, and outdoor electrical systems.
Use CANbus communication and proper 48V LiFePO4 settings.
For Victron systems, set the DIP switches, plug the communication harness’s grey RJ45 plug into the GX device’s BMS-CAN port (VE.Can 1 or 2 at 500 kbit/s on a Cerbo GX Mk2), confirm the Epoch battery appears on the device list, turn DVCC on, and set Epoch as the controlling BMS and the battery monitor. Program every charge source, Victron included, to the recommended 56.8V absorption, 54.0V float and 53.2V re-bulk values so charging stays correct if CAN communication is lost; for non-Victron systems, use a 48V LiFePO4-compatible charger or inverter charger set to the same values.
Verify your complete 48V system before installation.
Always confirm space (20.86 × 8.65 × 12.06 in; when replacing a Group 8D lead-acid battery, check tray fit, hold-down and lid clearance), mounting, cable clearance, terminal access, charger compatibility, inverter surge requirements, communication harnessing, fuse/breaker sizing (a DC-rated fuse or breaker close to the battery positive; the internal 270A fuse does not replace it), and local electrical standards before installation. Use matched batteries of the same model, age, capacity, and state of charge for parallel banks, and follow Epoch’s manual for DIP switch and communication setup.
Common questions about Victron integration, IP67 protection, inverter sizing, parallel expansion, heating, and 48V system compatibility.
Yes. The Epoch 48V 100Ah V2 Elite communicates over CAN bus at 500 kbit/s with compatible Victron GX devices, including Cerbo GX, Ekrano GX and Cerbo GX Mk2 installations. The included communication harness has a grey RJ45 plug for the GX device’s BMS-CAN port; on a Cerbo GX Mk2, use VE.Can 1 or VE.Can 2 and set the port speed to 500 kbit/s. Set the DIP switches on every battery, then turn on DVCC and set the controlling BMS and the battery monitor to Epoch: the battery then reports its status and sets the charge voltage and current limits of Victron chargers.
Most 48V server rack batteries are designed for dry, climate-controlled indoor environments. The Epoch V2 Elite is built for mobile and harsh environments with an IP67 dust-tight, immersion-rated enclosure, internal self-heating, Bluetooth monitoring, Victron CAN communication, and a rugged 20.86 × 8.65 × 12.06 in case for RV, marine, and off-grid systems.
A single Epoch 48V 100Ah battery stores 5.12kWh and is rated for 150A continuous discharge, about 7,680W DC at 51.2V before inverter losses, but only for up to 20 minutes at 150A and not for cycling; 300A is allowed for 30 seconds for surges. The DC input current is roughly the AC load divided by (battery voltage × inverter efficiency): a 2,000W load through an inverter assumed to be 90% efficient draws about 2,000 ÷ (51.2 × 0.90) ≈ 43A. If the inverter’s continuous DC input can exceed 150A, add batteries in parallel so the current per battery stays within the rating, and size cables, fusing and the disconnect for the maximum system current.
Yes. This model supports up to 16 batteries in parallel, allowing system builders to scale from one 5.12kWh battery up to a 1,600Ah / 81.92kWh 48V power bank. Use matched C48100A batteries of the same age, capacity, and state of charge, and set the DIP switches for the bank. This is a native 48V battery and should not be wired in series to create higher voltages.
No. The internal heater is powered by the charge source: when a charger is connected and the cells are below 0°C (32°F), the BMS holds off normal charging while the heater warms the cells, then resumes charging when they reach 5°C (41°F). It does not use stored battery capacity to keep itself warm while sitting or discharging. With self-heating, charging is supported from -22°F / -30°C ambient.
It can be an excellent upgrade for compatible 48V vehicles, golf carts, and electric marine propulsion systems, but compatibility must be confirmed first. Verify controller voltage, peak current (the battery allows 300A for 30 seconds), continuous current (150A for up to 20 minutes, 100A continuous charge), charger profile, physical fitment, terminal access, and manufacturer guidance before installation.
It is IP67 rated, meaning it is dust-tight and protected against temporary immersion in up to 1 m of water for 30 minutes. It is not rated for water jets, pressure washing or continuous submersion: install it where it stays dry in normal use, with all harness connectors fully seated, and do not treat it as submersible equipment or install it with damaged seals or open ports.
Yes. The Epoch Li-Ion app (iOS and Android), reached over Bluetooth 4.0 through the included battery gauge, shows state of charge, total voltage, total current and total capacity for the bank in its parallel view, and voltage, current, power, remaining capacity and warnings for each battery. Each battery appears as C48100A_ followed by its serial number; the Cells, History and Battery events screens add cell voltages, cell balance, temperatures and BMS events, and the About page installs firmware updates over the air.